Call Control problem

classic Classic list List threaded Threaded
3 messages Options
Reply | Threaded
Open this post in threaded view
|

Call Control problem

bay2x1
What seems to the problem with my call control configuration?

Feb 20 07:51:03 ws16 call-control[3173]: [-] Starting factory <callcontrol.rating.RatingEngineFactory instance at 0x828190c>
Feb 20 07:51:03 ws16 call-control[3173]: [Uninitialized] <twisted.internet.tcp.Connector instance at 0x82818ec> will retry in 10 seconds
Feb 20 07:51:03 ws16 call-control[3173]: [Uninitialized] Stopping factory <callcontrol.rating.RatingEngineFactory instance at 0x828190c>
Feb 20 07:51:13 ws16 call-control[3173]: [-] Starting factory <callcontrol.rating.RatingEngineFactory instance at 0x828190c>
Feb 20 07:51:13 ws16 call-control[3173]: [Uninitialized] <twisted.internet.tcp.Connector instance at 0x82818ec> will retry in 14 seconds
Feb 20 07:51:13 ws16 call-control[3173]: [Uninitialized] Stopping factory <callcontrol.rating.RatingEngineFactory instance at 0x828190c>
Feb 20 07:51:20 ws16 pulseaudio[2711]: module-alsa-sink.c: Increasing wakeup watermark to 353.20 ms
Feb 20 07:51:27 ws16 call-control[3173]: [-] Starting factory <callcontrol.rating.RatingEngineFactory instance at 0x828190c>
Feb 20 07:51:27 ws16 call-control[3173]: [Uninitialized] <twisted.internet.tcp.Connector instance at 0x82818ec> will retry in 18 seconds
Feb 20 07:51:27 ws16 call-control[3173]: [Uninitialized] Stopping factory <callcontrol.rating.RatingEngineFactory instance at 0x828190c>
Reply | Threaded
Open this post in threaded view
|

Re: Call Control problem

bay2x1
Was able to fix the problem by changing the rating engine to 127.0.0.1, previously I was using my own ip address. Using telneting to my own ip on port 9024 I got an error that says terminated by foreign host. When I change it to 127.0.0.1 it works fine.


bay2x1 wrote
What seems to the problem with my call control configuration?

Feb 20 07:51:03 ws16 call-control[3173]: [-] Starting factory <callcontrol.rating.RatingEngineFactory instance at 0x828190c>
Feb 20 07:51:03 ws16 call-control[3173]: [Uninitialized] <twisted.internet.tcp.Connector instance at 0x82818ec> will retry in 10 seconds
Feb 20 07:51:03 ws16 call-control[3173]: [Uninitialized] Stopping factory <callcontrol.rating.RatingEngineFactory instance at 0x828190c>
Feb 20 07:51:13 ws16 call-control[3173]: [-] Starting factory <callcontrol.rating.RatingEngineFactory instance at 0x828190c>
Feb 20 07:51:13 ws16 call-control[3173]: [Uninitialized] <twisted.internet.tcp.Connector instance at 0x82818ec> will retry in 14 seconds
Feb 20 07:51:13 ws16 call-control[3173]: [Uninitialized] Stopping factory <callcontrol.rating.RatingEngineFactory instance at 0x828190c>
Feb 20 07:51:20 ws16 pulseaudio[2711]: module-alsa-sink.c: Increasing wakeup watermark to 353.20 ms
Feb 20 07:51:27 ws16 call-control[3173]: [-] Starting factory <callcontrol.rating.RatingEngineFactory instance at 0x828190c>
Feb 20 07:51:27 ws16 call-control[3173]: [Uninitialized] <twisted.internet.tcp.Connector instance at 0x82818ec> will retry in 18 seconds
Feb 20 07:51:27 ws16 call-control[3173]: [Uninitialized] Stopping factory <callcontrol.rating.RatingEngineFactory instance at 0x828190c>
Reply | Threaded
Open this post in threaded view
|

Re: Call Control problem

Luci Stanescu
Hello

bay2x1 wrote:

> Was able to fix the problem by changing the rating engine to 127.0.0.1,
> previously I was using my own ip address. Using telneting to my own ip on
> port 9024 I got an error that says terminated by foreign host. When I change
> it to 127.0.0.1 it works fine.
>
> bay2x1 wrote:
>> What seems to the problem with my call control configuration?
>>
>> Feb 20 07:51:03 ws16 call-control[3173]: [-] Starting factory
>> <callcontrol.rating.RatingEngineFactory instance at 0x828190c>
>> Feb 20 07:51:03 ws16 call-control[3173]: [Uninitialized]
>> <twisted.internet.tcp.Connector instance at 0x82818ec> will retry in 10
>> seconds
>> Feb 20 07:51:03 ws16 call-control[3173]: [Uninitialized] Stopping factory
>> <callcontrol.rating.RatingEngineFactory instance at 0x828190c>

The messages you've encountered state that the connection to the rating
engine could not be established and it's retrying to connect. I will
change the messages to something that is more easily interpreted.


--
Luci Stanescu